HP Smart array CLI commands

 

HP Smart array CLI commands

Show configuration

/opt/hp/hpssacli/bin/hpssacli ctrl all show config

Controller status

/opt/hp/hpssacli/bin/hpssacli ctrl all show status

Show detailed controller information for all controllers

/opt/hp/hpssacli/bin/hpssacli ctrl all show detail

Show detailed controller information for controller in slot 0

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail

Rescan for New Devices

/opt/hp/hpssacli/bin/hpssacli rescan

Physical disk status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status

Show detailed physical disk information

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail

Logical disk status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status

View Detailed Logical Drive Status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show

Create New RAID 0 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0

Create New RAID 1 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

Create New RAID 5 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5

Delete Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete

Add New Physical Drive to Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7

Add Spare Disks

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7

Enable Drive Write Cache

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable

Disable Drive Write Cache

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable

Erase Physical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase

Turn on Blink Physical Disk LED

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on

Turn off Blink Physical Disk LED

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off

Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0

Enable smart array write cache when no battery is present (No-Battery Write Cache option)

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable

Disable smart array cache for certain Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable

Enable smart array cache for certain Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable

Enable SSD Smart Path

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable

Disable SSD Smart Path

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable

留言